Features

High-capacity rotors for CR7N

Rotor type Rotor type Nominal capacity
Fixed angle rotor R7A 6 L (1,000 mL PP/PC wide mouth bottle x 6 bottles)
Swinging bucket rotor R5S2 6 L (1,000 mL PP/PC bottle x 6 bottles)
400mL MAP bag x 6 bags or 400mL blood bag x 6 bags
R4SS2 500 mL blood bag x 8 bags
R5S3 400 mL blood bag x 12 bags

Fixed Angle Rotor model R7A (1,000ml x 6 bottles)

    • Nominal Capacity : 6L (1,000ml x 6 bottles)
    • Actual Capacity : 5.4L (900ml x 6 bottles)
    • Max. Speed : 7,000rpm / Max. RCF : 11,100 xg
    • Light-weight aluminum body (Net weight : 18.7kg)
    • Exclusive rotor for wide-mouth 1000PP bottle and 1000PC bottle

Swinging Bucket Rotor model R5S2 (1,000ml x 6 bottles)

    • Nominal Capacity : 6L (1,000ml x 6 bottles)
    • Actual Capacity : 5.4L (900ml x 6 bottles)
    • Max. Speed : 4,200rpm / Max. RCF : 5,150 xg
    • "1000AL bucket (B)" (sold separately) for wide-mouth 1000PP bottle and 1000PC bottle
    • "MAP bucket" (sold separately) for 400ml CPD-SAGM blood bag : 1 bag/bucket

Wide-mouth 1000PP bottle and 1000PC bottle

    • Wide-mouth design for easy collection of pellets or cleaning
    • Selectable bottle's material; PP or PC
    • Exclusive cap for easy loading/unloading the bottles

Swinging Bucket Rotor model R4SS2 (Exclusive rotor for blood bags)

    • Capacity : 2 x 500ml CPD-SAGM blood bags / bucket x 4 buckets (total 8 bags / rotor)
    • Max. Speed : 4,400rpm / Max. RCF : 5,350 xg
    • Improved design of the bucket for longer lifetime (PAT. pending)
    • Optional shield cap (upcoming product)

User-friendly function

Function name Description
User lockout You can control user access (for GMP/GLP compliance).
Operation history The centrifuge can automatically store an operation history 
(up to 100 operation parameters for past operations). 
You can re-use the operation history (  Patented feature   ).
USB/LANcommunications Option You can load the operation history data stored in the centrifuge to
a commercial USB memory stick in CSV format (for GMP/GLP compliance).
You can manage operation results through LAN communication 
(for GMP/GPL compliance).
Indicator lamp Option You can even check the current centrifuge status 
from a remote location with this indicator lamp.
Auto standby Ecology You can lower the electric power consumption of the centrifuge 
when the auto standby is selected.

User-friendly Design

Easy operation with color touch-sensitive LCD

  • Color touch-sensitive LCD and GUI (graphic user interface) with high contrast against a back screen in black color enables users to easily operate the system or select various menus and functions by touching an icon on the display. Of course, operation status is identified at a glance by intelligible screen design.

Programmed operation

  • You can register 30 programs for programmed operation to the system. In addition to the 30 programs, you can set 3 programs of 3-step-mode operation. This function is useful for routine operations in production sites.

Pre-cool function (PAT)

  • This function maintains temperature inside the rotor chamber at 15 ºC with preventing from icing, in order to reduce electricity consumption and reach target temperature faster while the door is closed.

Automatic standby function

  • CR7N has automatic standby function in it. If the display is not touched for a set weight time, the system automatically deems backlight of the LCD and stop refrigerator (except at a running) so that system reduces approx.. 52% of standby electricity *.
  • Just press a button, so you can contribute to the energy saving.
  • * comparing with standby electricity consumption without automatic standby function under in-house test condition with door closed.

User administration

  • You can register up to 50 users into the memory. You can set access level and PIN of each user. There are three access levels, "Administrator", "Supervisor" and "User".

User lockout function

  • In case the user lockout function is enabled, only registered user can login the system by entering registered 4 digits PIN. It is a useful function to control user access to the system in production sites.

Pilot lamp (option)

    • Optional pilot lamp shows an operating status of the CR7N. High brightness LED lights offer higher visibility, an operating status of the CR7N is easily recognized by the operator at away from the centrifuge. It is useful for a production site. The pilot lamp lights in red, green and blue color, and indicate the status of stop, acceleration, running at a set speed, deceleration and alert by the color and luminous pattern.
    • Photo : synthetic image when all color-lamps light.

Data communication and operating log management (Option)

USB

    • Optional USB port is available. The system records up to 100 operating histories in its memory. The operating data can be output in CSV format through the USB port. (You can also browse operating histories on the display.)

LAN

  • Optional LAN port is also available. You can link CR7N to your PC through Ethernet or internet. Optional software "himac LogManager Ver.4.1 (network edition)" can be installed in your PC and operating history and data of CR7N can be easily managed by your PC.

himac LogManager Ver. 4.1 for Windows ® (Network Edition) - optional log management software

  • himac LogManager Ver. 4.1 for Windows ® (Network Edition) is useful and convenient software to manage real-time operating log of himac CP-NX series, CP-WX series, CS150NX, CS150FNX, CR22N, and CR7N. Maximum 16 units of abovementioned centrifuges can be registered to the software at once. As data communication between the centrifuges and PC is done via LAN, so there is no distance limitation to establish a network. You can easily establish the network configuration and relocation with commercially available LAN devices. (Optional LAN board is required for the centrifuges.) It means you can manage the operation log at the different location from the installation sites of the centrifuges.
  • The software is real-time log management software; recording period is selectable from 10 seconds to 5 minutes interval. Of course, the software supports U.S. FDA 21 CFR Part 11, following functions are available;
  •  
  • Encrypted data files etc.
  • Audit trail
  • Encrypted data files etc.
  •  
  • Compatible OS;
  • Windows® 7 and Windows® 8
  • Windows® 7, Windows® 7 and Windows® 8 are registered trademark of Microsoft Corporation in the United States and other countries.

Specifications

Max. Speed 7,000 rpm
Max. RCF 11,100 xg (R7A rotor)
Max. Nominal Capacity 6,000 mL (R7A rotor or R5S2 rotor)
Speed Control Range from 300 to 7,000 rpm
Temperature Set Range from -20 to +40 °C
Timer Set Range "min:sec" unit mode : from 1 second to 99 min. 59 sec. with HOLD function
"hr:mm" unit mode : from 1 min. to 99 hrs 59 min. with HOLD function
ACL/DCL mode ACL : 9 modes / DCL : 9 modes with coasting
Program Function 30 programs, with RCF / g�Esec function
User Lockout Function available
Machine Log Management Function available
Driving Motor Induction Motor (inverter-controlled)
Refrigerator Fully enclosed (Refrigerant : R410A)
Safety Device Door interlock, dual-overspeed detector, imbalance detector, and over-temperature detector
Display Color touch-sensitive LCD *1
Applicable Standard CE marking qualified
Product Safety : EN61010-1 and EN61010-2-020
Electromagnetic compatibility : EN61326-1
Dimension 730 (W) x 845 (D) x 928 (H) mm
(with optional rear duct *2 : 730 (W) x 948 (D) x 928 (H) mm)
(from bottom to the chamber inlet : 869 (H) mm)
(with optional pilot lamp : 1,250 (H) mm)
Weight 320 kg
Power Requirement Single phase, AC 200/208/220/230/240 V +/-10%, 50/60Hz
Ambient Temperature Ambient temperature for operation : from 2 to 40 ºC
Ambient temperature for performance guarantee : from 15 to 25 ºC
Catalog CR7N catalog (PDF:1,500kb)
    Note:* CR7N has no RTC functions.
  • *1 CR7N satisfies CE marking requirements. The CE marking is an international symbol, which shows that the product conforms to EC directives.
  • *2 The rear duct is optional. This can reduce their cooling ability degradation when centrifuges are aligned.
  • *3 Please note that the LCD panel may contain a few dead or stuck pixels.

Rotors for CR7N


Type Fixed angle rotor Swinging bucket rotor
Model R7A R5S3 R5S2 R4SS2
Tube / Bottle 1000PP bottle (WM)
1000PC bottle (WM)
*2
400 mL
blood bag
(marketed product)
400 mL
blood bag
(marketed product)
1000PP bottle
1000PC bottle
*3
400 mL
MAP bag
(marketed product)
500 mL
blood bag
(marketed product)
Bucket - Exclusive bucket
(6 pcs/set)
Standard accessories
1000AL bucket (B)
(6 pcs/set)
P/N:S302160A
Sold separately
MAP bucket
(6 pcs/set)
P/N:S304829A
Sold separately
Exclusive bucket
(4 pcs/set)
Standard accessories
Inner cup - Oval inner cup (400)
(6 pcs/set)
Standard accessories
Inner cup (L)
(6 pcs/set)
P/N: S305557A
Sold separately
- MAP inner cup
(6 pcs/set)
P/N:S304843B
Sold separately
500 mL inner cup
(4 pcs/set)
Standard accessories
Max. speed
(rpm)
7,000 4,200 4,200 3,800 4,400
Max. RCF
(xg)
11,100 5,030 5,150 4,210 5,350
Nominal
capacity
6,000 mL
(1,000 mL x 6 bottles)
400 mL
blood bag
x12 bags
400 mL
blood bag
x6 bags
*4
6,000 mL
(1,000 mL
x6 bottles)
*4
400 mL
MAP bag
x6 bags
500 mL
blood bag
x8 bags
Weight
(kg)
18.7 32
(buckets included)
28 (buckets not included) 31
(buckets included)
Max. Imbalance
Tolerance *1
(gxpcs)
6x3 50/pairx3 50/pairx3 50/pairx2
Product No. 904367D0 904358D0 90431610 90437610
    Notes:
  • *1: Max. imbalance tolerance means allowable weight difference of tubes, bottles and buckets between the buckets in symmetry position.
  • *2: 6 sets 1000PP bottle (WM) including 1000PP cap (WM) are standard accessories of R7A rotor.
  • *3: 1000PP/PC bottles are not standard accessories of R5S2 rotor. Please order them separately..
    ・6 sets 1000PP bottle (P/N: 337155A) ・6 sets 1000PC bottle (P/N: 339420A)
  • *4: The speed of R5S2 rotor is limited by the weight of contents in bucket (the total weight of inner cup, bottle, blood bag and sample). When the total weight is over 1,000 g, R5S2 rotor cannot be used at the maximum speed. Please refer to the instruction manual according to the allowable speed.